. For your convenience we provide a list of State Certified Backflow Assembly Testers in our area. The community of Houston is nestled in the beautiful Bulkley Valley amongst some of BC's finest outdoor recreational opportunities. state. A premises-isolation RPBA must be installed on all water service connections that pose a risk to health. between one and 5-feet AFF, the assembly must be installed at water service entrance elevation. endstream
endobj
176 0 obj
<>
endobj
177 0 obj
<>/ProcSet[/PDF/Text/ImageB]/XObject<>>>/Rotate 0/Type/Page>>
endobj
178 0 obj
<>stream
Efrain Torres, Environmental Investigator IV. Assemblies installed directly on vertical subgrade risers, or off a riser which enters the space at less than one foot and necessitates the addition of a vertical run of pipe to be raised to observe the required 12 minimum elevation, must be approved for vertical installation. While mixing a batch of pesticide, a worker pushed a garden hose into the tank until it touched the bottom. As determined by the Water Bureau, part #8197, 36 X 36 or #8197-Double, 36 X 74 frame and covers may be required. See something we could improve onthis page? Under normal operation water flows from the City of Houston waterlines to the water customers. There are more than 30,000 backflow prevention assemblies in use in the Tucson Water service area. rescheduled. prevent backflow. Garden hoses and irrigation systems are common concerns, but there are other common residential sources of cross connections, too. In the case of parallel Reduced pressure assemblies the lower of the two will need to extend beyond the 4 minimum clearance behind to accommodate a drain assembly for relief valve orifice of the assembly above. Cross-Connection Control Program. 12. A RPBA must be installed on all service connections to industrial premises where complex (degree of complexity to be determined by the Water Bureau) intricate plumbing systems exist. Planning, outreach and education, strategic, and technology projects. Water and pesticides flowed from the pesticide tank back through the hose and into the water lines of the residence. {R/ONU1#>he I5ce;, For parking lot, driveway, loading dock applications and/or heavy commercial traffic applications, a minimum of EJ USA Inc. #8217, 36 X 36 or #8217-Double 36 X 74 frame and covers or equivalent must be used. All vaults and enclosures for backflow assemblies must be kept free of any debris and/or objects that interfere with these installation requirements and those applicable to OAR 333-061-0071. hbbd``b`A*
$XN HqH2} . Finding a reliable backflow tester doesnt have to be a risky or time-consuming process. connected through a backflow-prevention assemblywithout which, the stagnant water, and anything in it, from the sprinkler system could be drawn into the potable-water supply for your home. Local business owners can create quote requests for a backflow services. These will allow for necessary clearance for ladders in single assembly installations. Backflow Prevention FAQs. Please follow the prompts andhave the project numberandyour scheduling PIN readily available. 751 0 obj
<>
endobj
Tablet PCs running Windows 10 must run Windows 10 Home, Pro, or Enterprise. This reversal of flow direction is known as backflow. Preventing backflows is important for protecting drinking water quality. The proposed installation of a RPBA in an area that may be subject to flooding must be reviewed and approved by Portland Water Bureau Water Quality Inspection prior to installation. The relief-valve must be located 12" above the top of the vault drain opening. By replacing pipes before they break, taking steps to ensure that system pressures do not fall during periods of high demand, and asking for the cooperation of customers when there is a risk that system pressures could fall below safe levels, your public water system operator reduces the risk of backflow. Suite 100 A sump pump will be required if vaults are unable to be kept free of standing water. Back siphonage is the result of supply pressure being lowered An individual may substitute one year of required experience with: 1 year of College credit (32 Semester Hours), 20 Hours of Approved Training in addition to the required 40-hour Training Course. 8. Customer water can be exposed to chemicals, microbes and other harmful substances through sinks, irrigation systems, toilets, showers, washing machines, hose bibs, or through commercial fixtures including boilers and cooling towers. You may also e-mail your question or comment to PDWS@tceq.texas.gov. thermal expansion increases the pressure. Put simply, a backflow preventer ensures water inside fire sprinklers, irrigation systems, and other water-based . Luckily, this is where it stopped: The worker mixing the pesticide realized the danger and alerted the utility workers, who closed the flush valve before the contamination reached the citys distribution line. Get listed and meet new customers. Name of Property: Property Address: City, State, Zip: , . Some appliances have built-in backflow prevention for this reason, but many do not. The bottom of the discharge end of the bore-sight drain must be at least 12 above the flood rim of any physical feature such as but not limited to; ponds, fountains, lakes, rivers, swales and/or any other type of receiving vessel. A reduced pressure type backflow assembly will be required on services to premises with piping systems adjacent to waterways that may be subject to immersion due to periods of highwater incidents. Provide fence and gate details (drawings) for all types of . All certified backflow prevention assembly testers play an important role in protecting the City of Houston water customers. The relief-valve must be located 12 above the top of the vault drain opening. The Cross-Connection Control Subcommittee advises us in this effort. Where it is possible for a fire sprinkler system to be connected to or be augmented by any auxiliary water source a RPDA will be required. A Customer Service Inspection Certificate (CSI) is used to document the findings of a Customer Service Inspection. 205 0 obj
<>/Filter/FlateDecode/ID[]/Index[175 60]/Info 174 0 R/Length 134/Prev 362807/Root 176 0 R/Size 235/Type/XRef/W[1 3 1]>>stream
Backflow occurs when water from your property's plumbing flows backward into the City's water system. A RPBA may required to be installed on any water service that is considered potable and provides for the use of water as a medium for purposes other than potable drinking water. An inspection fee must be paid to the Water Bureau prior to replacement of an existing assembly or newly installed assembly on a dedicated fire service. Apply in person at 1002 Washington Avenue, Houston, TX 77002 or at one of the Satellite Offices. Assemblies must be readily accessible with adequate room for testing and maintenance: Assemblies 2 inches and smaller (excludes DCDAs, see next bullet) must maintain at least 4-inches clearance on all sides and at both ends, respectively. Advance Pay Account holders may apply for the permit by fax. 2. The bore-sight drain must never be connected to a sewer of any kind, catch basins, sumps, or dry wells. g"`Q CL!s?gp\W80dpQ%0e8iF bS24IP s0 K
By taking steps to control cross connections and prevent the possibility of backflow at your home, you will help to protect the public water supply and ensure that your family continues to enjoy safe drinking water. Only approved Double Check Valve and Reduced Pressure type backflow assemblies, may be used for premises-isolation backflow protection. Effective September 1, 2017, pursuant to TCEQ Reg-521 "Criminal History Guidelines", those with a felony criminal history should contact TCEQ Licensing Division prior to registering for a training course. Backflow is the unintended flow of water from any domestic, industrial or institutional piping system into a drinking water supply system. The simplest method to prevent backflow is to have your backflow assembly tested on an annual basis. When a RPBA is installed in a vault or enclosure in a berm or hillside, a horizontal boresight drain to daylight must be provided. Of the 24 hours, 8 hours must be practical skills (hands-on) training. Find more information related to vault lid and door applications under the section Additional installation requirements for vaults and enclosures. Click Here for a copy of the COH Backflow Preventer Test Report and Maintenance Form. State rules and City Codes require you to: Backflow Assembly Installation Requirements. Normally, water travels in one direction, from treatment plants, through water mains, then to each customers service connection. When jobs are completed through SwiftQuote, the work order is automatically submitted to participating jurisdictions through SwiftComplys compliance software. Huntington Backflow Prevention Valves Project: $6,358,000: West Virginia: 2. All assemblies 2 and smaller (Excludes fire service assemblies, see information under fire sprinkler services) must be installed no more than 24 below finished grade. Backflow Prevention Assembly Test and Maintenance Report(, Customer Service Inspections: A Guide for Public Water Systems (TCEQ publication, Backflow Protection on Fire Prevention Systems (TCEQ publication, A Public Water System Guide to Preparing a Backflow-Incident Emergency-Response Plan (TCEQ publication, A Public Water System Guide to Responding to a Backflow Incident (TCEQ publication, Establishing and Managing an Effective Cross-Connection Control Program (TCEQ publication. %%EOF
Have a High School Diploma or Equivalent Certificate, Pass an examination *Written exam must be taken at a TCEQ regional office or proctored computer-based testing facility as of May 2, 2016, Work at least two years in an approved area. Highline Water District 3. The relief-valve must be located 12 above finished slab elevation. Backflow is the undesirable reverse flow of non-potable (non-drinkable) water or other substances that can contaminate the drinking or public water system due to a cross connection in the piping. Emergency: 206-824-0375 175 0 obj
<>
endobj
All students registered for this class will receive a copy of the USC 10th Edition. Typically, backflow prevention assemblies are required for plumbing system connections that contain industrial fluids or chemicals, irrigation systems, fertilizers, or auxiliary water sources (including reclaimed water). hb``a``d`c`Lcb@ !FV&m3@(Z R pGAsD /
6/`9ARTkX[Turd_0 '
14. 10. Office Hours . The City of Portland ensures meaningful access to City programs, services, and activities to comply with Civil Rights Title VI and ADA Title II laws and reasonably provides: translation, interpretation, modifications, accommodations, alternative formats, auxiliary aids and services. Upon job completion, the provider uploads service details to SwiftQuote, and you can either pay online via credit card or offline directly to the provider. TCEQ regulations are the minimum requirement. Fire systems that incorporate the use of storage tanks must be equipped with a RPDA and are required to be installed at the service connection/point-of-delivery to the premises as outlined herein. In addition to City Code Title 21 and Title 28, OAR 333-061-0070, Section 14, will apply to all existing premises-isolation backflow assembly installations. Fire sprinkler system piping will be reviewed on a case-by-case basis regarding sleeving. All rights reserved. The drain must discharge to finished grade and/or be above the 100-year flood plain, whichever is greater. regarding the abilities, performance or quality of service of the 234 0 obj
<>stream
The RPDA must be installed at the service connection/point-of-delivery to the premises as outlined herein and as defined by OAR Chapter 333-061-0020. 2. How can backflow be prevented? A reduced pressure type assembly must be installed on all water service connections to premises with high-rise buildings (high-rise building: where a building is 75-feet or greater above its lowest finished-floor (slab) elevation to top of structure). Vacuum Breaker/backflow preventer HPWCODE1100 About Apply Inspections Contact Plan Review Not Required Inspection Required Renewal Not Required Fee $31.95 for first three; $10.65 each additional. susceptible to back-ups, proper backflow prevention shall be designed. Installations must meet Occupational Safety and Health Administration and State of Oregon Occupational Safety and Health codes. Assemblies must be installed on private property at the property line (service connection/point-of-delivery as defined in OAR), on the centerline of the city water service as it runs perpendicular from the R.O.W. . Statewide Links: Texas.gov How Cross-Connection and Backflow Can Lead to Contaminated Water, TCEQ's regulations for irrigation systems, database of licensed Customer Service Inspectors, Cross-Connection Control (CCC) Subcommittee, Table Listing Common Cross-Connection Hazards, Recommended Practice for Backflow Prevention and Cross-Connection Control, Foundation for Cross-Connection Control and Hydraulic Research, Guide to Cross Connection Protection Devices and Assemblies: Application and Selection, Rules and Regulations for Public Water Systems. prevented by using a backflow-prevention 7. | Texas Veterans Portal If the fire sprinkler service is fully metered (a meter approved by the Water Bureau for fire flow application and billing purposes) a Double Check Valve Assembly (DCVA) or Reduced Pressure Backflow Assembly (RPBA) may be installed depending on sprinkler system type. The drain must never be less than 12 above the flood elevation of a water source, swale or any other catchment subject to overflow/flooding. Premises-isolation backflow assemblies must be those approved by University of Southern California Foundation for Cross-Connection Control and Hydraulic Research (USC) and the Oregon Health Authority (OHA). Contact Information 941-263-6884 . The riser/supply pipe must be installed 12 from the property frontage foundation wall to the centerline of pipe on the centerline of the city water service as it runs perpendicular from the R.O.W. Schedule CSI Inspections / Horario de Inspeccin CSI, Code Enforcement Officers & registered Sanitarian, Pipeline Assessment Certification Program (PACP), Surface PRO 2 or higher, running Windows 8.1 or higher, An internet connection broadband wired or wireless (3G or 4G/LTE), Speakers and a microphone built-in, USB plug-in, or wireless Bluetooth. Backpressure backflow caused by downstream pressure that exceeds the upstream supply pressure in the drinking or public water systems due to a high pressure source. In each of these cases, if backflow happens, your households water lines could be contaminated. This occurs when a supply is interrupted . the reverse direction. 13. City of Temple Public Works Service Center, City of Webster Public Works Dept Service Center. %%EOF
Back-siphonage backflow caused by a negative pressure (i.e., a vacuum or partial vacuum) in the drinking or public water system. You can find one from our, If you install your own system, have a licensed BPA tester confirm that the BPA is installed and operating properly. the system pressure has been increased by For horizontal installations, and for assemblies which are not approved for vertical up installation, the riser must be equipped with a single 90-degree elbow and the assembly is to be no more than the pipe diameter in inches beyond the centerline (or outlet side of the) elbow to accommodate horizontal installations, excepting only the addition of a wye-strainer, flood control shut off valve or other, necessary appurtenance. However, certain pressure variations in the public water supply can cause water to flow in the opposite direction. 4. Click Here for the requirements to register with the City of Houston as a backflow prevention assembly tester. Foundations, footings, slabs and/or walls must be sleeved or core-drilled to accommodate code compliant riser/supply pipe entrance locations. Services supplying premises that are equipped with frost-free drain-back yard hydrants and/or Sanitary Yard Hydrants must be equipped with a RPBA. SwiftQuote integrates with your municipality and uploads compliance records to the city on your behalf. If your property or business type is not included in the above list and you have a specific question about your legal requirements, please call 311 to have your inquiry directed to DEP. . All wires running from the bypass meter to the touchpad must be in conduit. Third-Party CSI Inspectors: Ray Harlow: 832-349-4465 Terry Blanchard: 281-889-1443 Taylor: 936-647-5852. If available, current GIS data will be used to make this determination. Vaults must accommodate 6-feet of vertical headroom or have hinged double door opening frame and covers that accommodate the entire lay length of the assembly. It is recommended when 2 and 1-1/2 Double Check Valve Assemblies (Excludes fire service assemblies, see information under fire sprinkler services) are installed below grade the Carson Industries plastic box #1730-18 be used or equivalent. Approved Areas per TCEQ (click link for more details): Operating or maintaining a Public Drinking Water System, Installing or repairing residential, commercial, or industrial drinking water treatment equipment, Installing or repairing lawn irrigation systems, Performing activities requiring a Master or Journeyman Plumbing license, Testing and repairing backflow prevention assemblies on fire suppression systems and lines. . All services considered non-potable and do not pose a risk to health. Copyright 2023 Houston Public Works. To remove the pesticide from the water lines of the customer, utility workers flushed those lines. When a Double Check Valve Assembly (DCVA) or a Double Check Detector Assembly (DCDA) is installed in a vault the following must be provided: 1. Your water systems role begins with good system maintenance and sound operations. Click Here to add a tester to your company. endstream
endobj
startxref
5. 2. A RPBA must be installed on domestic water services to premises where shell buildings are constructed or renovated when occupancy is undetermined at the time of construction and/or renovation. (Minimum Permit Fee is $91.05) Admin fee 31.32 Valid Period 180 Days Processing Time 1 business day Technical assistance in the area of cross-connection control is offered to public water systems by staff from our central office. (Minimum Permit Fee is $91.05). water service customers who are advised to use their own judgment It can be a serious health risk for the 0
All Double Check Detector Assemblies (DCDAs) and Reduced Pressure Detector Assemblies (RPDAs) required to be installed by the Portland Water Bureau must be equipped with a Water Bureau approved bypass meter and compatible touchpad. All exposed piping inside enclosures must be insulated with commercially manufactured closed-cell pipe insulation or a heat source must be provided. Splices must be made with 3M Scotchlok moisture resistant connectors, part number UR or UY or equivalent. For single & multiple assembly installations, refer to item #2 above to ensure proper ladder placement. some means. Kent, WA 98032 Enter your requirements and local pros will bid on your service, providing a quote to complete your request. 103 St. Philip Street PO Box B (29402) Charleston, SC 29403 Directions. contamination of potable water supplies with foul water. Above ground enclosure installations may have clearances less than those mentioned for vault installations, provided they are equipped with removable panels, doors and tops that create clearances equal to or greater than those described herein. Select the appropriate type of inspection and click the Submit button. . Vault/enclosure installations must be provided with adequate drainage and drains may not be connected to sewers of any kind, catch basins, below the flood rim of swales or riverbanks. To schedule inspections, contact the Interactive Voice Response (IVR) System at 713-222-9922. Premises-Isolation assemblies (those that directly protect the public water supply) must be installed on private property at the property line (service connection/point-of-delivery) on the centerline of the city water service, as it runs perpendicular from the right-of-way (R.O.W.).